ADASEAL INTERNATIONAL INC -- 100% RTV SILICONE -- 8030-00N055707
===================== Product Identification =====================
Product ID:100% RTV SILICONE
MSDS Date:04/19/1994
FSC:8030
NIIN:00N055707
=== Responsible Party ===
Company Name:ADASEAL INTERNATIONAL INC
Box:377
City:NEW JOHNSONVILLE
State:TN
ZIP:57154
Country:US
Info Phone Num:615-296-2291
Emergency Phone Num:615-296-2291
CAGE:ADASE
=== Contractor Identification ===
Company Name:ADASEAL INTERNATIONAL INC
Box:377
City:NEW JOHNSONVILLE
State:TN
ZIP:57154
Country:US
Phone:615-296-2291
CAGE:ADASE
============= Composition/Information on Ingredients =============
Ingred Name:SILANE, METHYL TRIACETOXY-; (METHYLTRIACETOXYSILANE)
CAS:4253-34-3
RTECS #:VV5000000
Fraction by Wt: 2%
OSHA PEL:N/K
ACGIH TLV:N/K
Ingred Name:ETHYLTRIACETOXYSILANE
Fraction by Wt: 2%
OSHA PEL:N/K
ACGIH TLV:N/K
Ingred Name:SILICA, AMORPHOUS, DIATOMACEOUS EARTH;(SILICA, AMORPHOUS)
CAS:61790-53-2
RTECS #:HL8600000
Fraction by Wt: 10%
OSHA PEL:20 MPPCF; Z-3
ACGIH TLV:10 MG/M3 TDUST
Ingred Name:NON-HAZARDOUS INGREDIENTS
OSHA PEL:N/K
ACGIH TLV:N/K
===================== Hazards Identification =====================
LD50 LC50 Mixture:LD50:(ORAL,RAT)>10,000 MG/KG
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:ACUTE:INGESTION:MAY CAUSE GASTRIC
DISTRESS. SKIN:UNCURED PRODUCT CONTACT WILL IRRITATE LIPS, GUMS,
AND TONGUE. UNCURED PRODUCT CONTACT MAY IRRITATE. INHALATION:CAUSES
MILD RESPIRATORY IRRITATION. EYE: UNCURED PRODUCT CONTACT IRRITES.
CHRONIC:NONE LISTED BY MANUFACTURER.
Explanation of Carcinogenicity:NOT RELEVANT.
Effects of Overexposure:SEE HEALTH HAZARDS.
Medical Cond Aggravated by Exposure:NONE KNOWN.
======================= First Aid Measures =======================
First Aid:INGEST:CALL MD IMMEDIATELY . SKIN:TO CLEAN FROM SKIN, REMOVE
COMPLETELY W/DRY CLOTH/PAPER TOWEL BEFORE WASHING W/DETERGENT &
WATER. GET MED ATTN IF IRRIT DEVELOPS. INHAL:REMOVE TO FRESH AIR.
EYE S:IMMED FLUSH W/PLENTY OF WATER FOR @ LEAST 15 MINS & GET MED
ATTN.
===================== Fire Fighting Measures =====================
Flash Point Method:CC
Flash Point:>212F,>100C
Extinguishing Media:WATER, WATER FOG, CO*2, FOAM.
Fire Fighting Procedures:USE NIOSH/MSHA APPROVED SCBA & FULL PROTECTIVE
EQUIPMENT .
Unusual Fire/Explosion Hazard:NONE KNOWN.
================== Accidental Release Measures ==================
Spill Release Procedures:WIPE OR SOAK UP IN INERT MATL & PUT IN CNTNR
FOR DISP. WASH WALKING SURFACES W/DETERGENT & WATER TO REDUCE
SLIPPING HAZ. WEAR PROPER PROT EQUIP AS SPECIFIED.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.
====================== Handling and Storage ======================
Handling and Storage Precautions:AVOID CONT W/SKIN & EYES. PROD
RELEASES ACETIC ACID DURING APPLIC & CURING. USE MECHANICAL VENT TO
STAY BELOW TLV OF 10 PPM ACETIC ACID.
Other Precautions:CAUTION! WEARERS OF CONT LENSES MUST NOT HANDLE
LENSES UNTIL ALL SEALANT HAS BEEN CLEANED FROM FINGERTIPS; RESIDUAL
SILICONE WILL TRANSFER TO LENSES & CAUSE SEV EYE IRRIT. UNCURED
PROD CONT IRRITATES EYES & SKIN. USE IN WELL VENT (SUPDAT)
============= Exposure Controls/Personal Protection =============
Respiratory Protection:NIOSH/MSHA APPROVED RESPIRATOR APPROPRIATE FOR
EXPOSURE OF CONCERN .
Ventilation:USE ONLY IN WELL VENTILATED AREA.
Protective Gloves:CLOTH GLOVES.
Eye Protection:ANSI APPRVD CHEM WORKERS GOGG .
Other Protective Equipment:EYEWASH STATIONS.
Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health
OTHER PRECAUT:AREA TO PREVENT IRRITATION BY VAPORS.
================== Physical/Chemical Properties ==================
Vapor Pres:<5 @77F
Spec Gravity:1.04 @77F
Solubility in Water:<0.1
Appearance and Odor:ALL COLORS, ACETIC ACID ODOR
Percent Volatiles by Volume:<5
================= Stability and Reactivity Data =================
Stability Indicator/Materials to Avoid:YES
OXIDIZING MATL CAN CAUSE REACTION. AIR/MOISTURE CAUSES CURING & ACETIC
ACID VAPORS FORM.
Stability Condition to Avoid:EXPOSURE TO AIR OR MOISTURE UNTIL READY TO
USE.
Hazardous Decomposition Products:SILICON DIOXIDE, CARBON DIOXIDE, AND
TRACES OF INCOMPLETELY BURNED CARBON PRODUCTS.
==================== Disposal Considerations ====================
Waste Disposal Methods:DISPOSAL SHOULD BE MADE IN ACCORDANCE WITH
FEDERAL, STATE, AND LOCAL REGULATIONS.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.