AMERICAN INDUSTRIAL SUPPLY INC -- DRY LUBE -- 9150-00N014964
===================== Product Identification =====================
Product ID:DRY LUBE
MSDS Date:01/01/1987
FSC:9150
NIIN:00N014964
=== Responsible Party ===
Company Name:AMERICAN INDUSTRIAL SUPPLY INC
Address:4623 BRAZIL STREET
City:LOS ANGELES
State:CA
ZIP:90039
Country:US
Emergency Phone Num:818-500-0961
CAGE:0ENL6
=== Contractor Identification ===
Company Name:AMERICAN INDUSTRIAL SUPPLY INC
Box:10996
City:BURBANK
State:CA
ZIP:91510-0996
Country:US
Phone:818-841-7788
CAGE:0ENL6
Company Name:INDUSTRIAL FLOOR FINISHES
Address:605 SPRINGS RD
City:BEDFORD
State:MA
ZIP:01730
Country:US
Phone:1-617-667-5161
CAGE:INDUS
============= Composition/Information on Ingredients =============
Ingred Name:METHYLENE CHLORIDE (SARA III)
CAS:75-09-2
RTECS #:PA8050000
Fraction by Wt: 45%
OSHA PEL:500 PPM/C,1000; Z2
ACGIH TLV:50 PPM, A2; 9192
EPA Rpt Qty:1000 LBS
DOT Rpt Qty:1000 LBS
Ingred Name:METHYL ALCOHOL (METHANOL) (SARA III)
CAS:67-56-1
RTECS #:PC1400000
Fraction by Wt: <1%
OSHA PEL:S,200PPM/250STEL
ACGIH TLV:S,200PPM/250STEL; 93
EPA Rpt Qty:5000 LBS
DOT Rpt Qty:5000 LBS
Ingred Name:METHYL CHLOROFORM (1,1,1-TRICHLOROEHANE) (SARA III)
CAS:71-55-6
RTECS #:KJ2975000
Fraction by Wt: 22%
OSHA PEL:350 PPM/450 STEL
ACGIH TLV:350 PPM/450STEL;9192
EPA Rpt Qty:1000 LBS
DOT Rpt Qty:1000 LBS
Ozone Depleting Chemical:1
===================== Hazards Identification =====================
LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:NO Ingestion:NO
Reports of Carcinogenicity:NTP:YES IARC:YES OSHA:NO
Health Hazards Acute and Chronic:INHALATION MAY RESULT IN DROWSINESS,
HEADACHES, NAUSEA, EYE AND LUNG IRRITATION.
Explanation of Carcinogenicity:DICHLOROMETHANE - IARC-2B;NTP-2
Effects of Overexposure:SEE HEALTH HAZARDS.
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.
======================= First Aid Measures =======================
First Aid:INHAL: REMOVE TO FRESH AIR. SKIN/EYE: FLUSH WITH WATER FOR AT
LEAST 15 MINUTES . INGEST: CALL MD IMMEDIATELY .
===================== Fire Fighting Measures =====================
Flash Point Method:TOC
Flash Point:NONE UP TO 92F
Extinguishing Media:FOAM, DRY CHEMICAL, CO*2.
Fire Fighting Procedures:WEAR NIOSH/MSHA APPROVED PRESSURE DEMAND SCBA
AND FULL PROTECTIVE EQUIPMENT .
Unusual Fire/Explosion Hazard:THERMAL DECOMPOSITION PRODUCTS MAY
INCLUDE HCL AND PHOSGENE .
================== Accidental Release Measures ==================
Spill Release Procedures:SOAK UP ON APPROPRIATE ABSORBENT MATERIAL.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.
====================== Handling and Storage ======================
Handling and Storage Precautions:DO NOT STORE WHERE TEMPERATURE EXCEEDS
120F.
Other Precautions:SEE LABEL. NO SMOKING IN AREA OF USE. DO NOT USE IN
THE GENERAL VICINITY OF ARC WELDING, OPEN FLAME OR HOT SURFACES.
HEAT AND/OR UV RADIATION MAY CAUSE THE FORMATION OF HCL AND
PHOSGENE .
============= Exposure Controls/Personal Protection =============
Respiratory Protection:NONE REQUIRED AS LONG AS NOT USED IN SMALL
CLOSED AREA. USE NIOSH/MSHA APPROVED RESPIRATOR APPROPRIATE FOR
EXPOSURE OF CONCERN .
Ventilation:GENERAL VENTILATION IS ADEQUATE.
Protective Gloves:NONE UNLESS PROLONGED CONTACT.
Eye Protection:CHEMICAL WORKERS GOGGLES .
Other Protective Equipment:NONE SPECIFIED BY MANUFACTURER.
Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health
NONE SPECIFIED BY MANUFACTURER.
================== Physical/Chemical Properties ==================
HCC:V3
Boiling Pt:B.P. Text:92.0F,33.3C
Spec Gravity:1.28
Evaporation Rate & Reference:>1 (WATER=1)
Solubility in Water:NEGLIGIBLE
Appearance and Odor:BLACK LUSTROUS LIQUID, CHARACTERISTIC ODOR.
Percent Volatiles by Volume:92
================= Stability and Reactivity Data =================
Stability Indicator/Materials to Avoid:YES
STRONG OXIDIZING AGENTS.
Stability Condition to Avoid:TEMPERATURES ABOVE 120F.
Hazardous Decomposition Products:SO*X ABOVE 700F. HCL AND PHOSGENE .
==================== Disposal Considerations ====================
Waste Disposal Methods:IN ACCORDANCE WITH LOCAL, STATE AND FEDERAL
REGULATIONS.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.