GO-JO INDUSTRIES INC -- CREAM HARDENER -- 8030-00N003758
=====================  Product Identification  =====================

Product ID:CREAM HARDENER
MSDS Date:01/01/1985
FSC:8030
NIIN:00N003758
=== Responsible Party ===
Company Name:GO-JO INDUSTRIES INC
Address:144 CUYAHOGA ST
Box:991
City:AKRON
State:OH
ZIP:44309
Country:US
CAGE:02905
=== Contractor Identification ===
Company Name:GOJO INDUSTRIES, INC.
Box:991
City:AKRON
State:OH
ZIP:44309-0991
Country:US
Phone:330-920-8100 EXT 352
CAGE:02905

=============  Composition/Information on Ingredients  =============

Ingred Name:BENZOYL PEROXIDE
CAS:94-36-0
RTECS #:DM8575000
Fraction by Wt: 50%
ACGIH TLV:5 MG/CUM

Ingred Name:BUTYL BENZYL PHTHALATE  (SARA III)
CAS:85-68-7
RTECS #:TH9990000
Fraction by Wt: 50%
EPA Rpt Qty:100 LBS
DOT Rpt Qty:100 LBS

=====================  Hazards Identification  =====================

Effects of Overexposure:EYE/SKIN: IRRITATION

=======================  First Aid Measures  =======================

First Aid:EYE: FLUSH WITH WATER 15 MINUTES,CONSULT PHYSICIAN. SKIN:
    WASH WITH SOAP & WATER. INGESTION: ADMINISTER AN EMETIC AND GET
    MEDICAL ATTENTION.

=====================  Fire Fighting Measures  =====================

Flash Point:NONE
Extinguishing Media:CLASS B & WATER.

==================  Accidental Release Measures  ==================

Spill Release Procedures:SOAK UP SPILLED MATERIAL WITH NON-COMBUSTIBLE
    MATERIAL,SUCH AS PERLITE OR VERMICULITE.

======================	Handling and Storage  ======================

Handling and Storage Precautions:STORE IN COOL AREA BELOW 90F/32C &
    AWAY FROM SOURCES OF HEAT,STRONG OXIDIZING & REDUCING AGENTS.

=============  Exposure Controls/Personal Protection  =============

Ventilation:MEHCANICAL,GENERAL.
Eye Protection:RECOMMENDED
Supplemental Safety and Health
VERY FIRE RESISTANT-NEGLIGIBLE EXPLOSION HAZARD.

==================  Physical/Chemical Properties  ==================

Spec Gravity:1.2
Solubility in Water:SLIGHT
Appearance and Odor:CREAMY PASTE-ORANGE
Percent Volatiles by Volume:<1

=================  Stability and Reactivity Data  =================

UNCONTROLLED CONTACT WITH POLYMERIZABLE

====================  Disposal Considerations  ====================

Waste Disposal Methods:BY METHODS CONSISTENT WITH LOCAL,STATE & FEDERAL
    REGULATIONS.

 Disclaimer (provided with this information by the compiling agencies):
 This information is formulated for use by elements of the Department
 of Defense.  The United States of America in no manner whatsoever,
 expressly or implied, warrants this information to be accurate and
 disclaims all liability for its use.  Any person utilizing this
 document should seek competent professional advice to verify and
 assume responsibility for the suitability of this information to their
 particular situation.